Occupied Building Risk Assessment (OBRA) Services for Hazard Sites

OBRA CONSULTANTS

What Is an Occupied Building Risk Assessment?

An Occupied Building Risk Assessment is a structured evaluation of the risks to people located within buildings that may be exposed to fire, explosion or toxic release hazards arising from nearby process activities. OBRA assesses whether buildings intended for occupancy provide adequate protection against foreseeable events and whether additional measures are required to ensure risks are reduced to ALARP.

It applies to both permanent and temporary buildings where people work, gather or take refuge.

Industrial facilities handle flammable, explosive and toxic materials. In the event of an accidental release, the consequences to building occupants can include:

  • Structural damage from blast overpressure
  • Flying glass or building debris
  • Thermal radiation affecting escape routes
  • Smoke or toxic atmosphere ingress

Industry experience has shown that inadequately assessed temporary or permanent buildings can significantly increase the risk to personnel during major incidents.

Occupied buildings that could be exposed to credible fire, explosion or toxic release scenarios should be assessed to determine whether their occupants are adequately protected.

Guidance from the Chemical Industries Association, alongside API RP 752 (Management of Hazards Associated with Location of Process Plant Permanent Buildings) and API RP 753 (Management of Hazards Associated with Location of Process Plant Portable Buildings), supports assessing occupied buildings that could be exposed to fire, explosion or toxic release hazards.

For UK sites operating under COMAH, demonstrating that occupied buildings are suitably protected forms part of the wider obligation to reduce risks to ALARP and to protect people and the environment.

Operators are also expected to review and update their OBRA periodically, particularly where site activities, inventories or building usage change.

An OBRA is typically required:

  • When installing a new permanent or temporary building
  • When assessing the suitability of existing occupied buildings
  • When site inventories or process conditions change
  • During major plant modification
  • As part of COMAH Safety Report updates
  • Following incidents or regulatory review

Early assessment is particularly important where buildings are being located within proximity of process units.

A structured OBRA typically includes:

  1. Identification of all buildings intended for occupancy
  2. Definition of credible fire, explosion and toxic release scenarios
  3. Consequence modelling to assess blast, thermal and toxic effects
  4. Estimation of risk to occupants
  5. Evaluation of existing building protection measures
  6. Identification of additional risk reduction measures
  7. Cost benefit analysis where appropriate
  8. Demonstration that residual risk is ALARP

This structured process supports defensible decision making and clear communication with regulators and leadership.

A comprehensive OBRA evaluates:

  • Explosion overpressure impacts on building structure
  • Thermal radiation exposure from fire scenarios
  • Toxic gas dispersion and ingress pathways
  • Structural integrity and blast resistance
  • Building siting relative to hazard sources
  • Occupancy levels and duration
  • Emergency egress and access routes
  • Toxic refuge location and accessibility
  • Risk reduction options and ALARP demonstration

The objective is to ensure that occupants are adequately protected from credible major accident scenarios.

OBRA is relevant across a range of sectors, including:

  • Chemical manufacturing
  • Distilled spirits production (e.g. occupied control rooms or site offices near spirit handling and storage areas)
  • Food and drink processing
  • Life sciences and pharmaceutical facilities
  • Energy and infrastructure projects

It is particularly valuable in brownfield environments, where existing constraints influence design decisions.

OBRA support may include:

  • Initial identification of occupied buildings
  • Full OBRA report
  • Review or update of existing OBRA documentation
  • Risk reduction and mitigation recommendations
  • ALARP demonstration
  • Inputs to COMAH Safety Reports
  • Support during regulatory engagement

Outputs are structured to be clear, proportionate and regulator ready.

Frequently Asked Questions

Quick answers to questions you may have about our services

While OBRA itself is not a standalone regulation, it is widely recognised under CIA and API guidance and forms part of demonstrating compliance with major hazard regulations such as COMAH.

Yes. Temporary buildings intended for occupancy should be assessed if they are located within areas exposed to fire, explosion or toxic hazards.

OBRA should be reviewed periodically and whenever there are significant changes to process inventories, site layout, building occupancy or operating conditions.

No. OBRA is relevant to any major hazard facility where buildings may be exposed to fire, explosion or toxic release risks, including distilleries, pharmaceutical plants and energy installations.

CONTACT US

Talk to our Process Safety Team