Functional Safety Assessment Consultancy Services

FUNCTIONAL SAFETY CONSULTANT, SUPPORTING ACROSS THE ASSET LIFECYCLE

What Is Functional Safety?

Functional safety is the part of overall system safety that depends on automatic protection systems responding correctly to inputs or failures in a predictable manner. In process industries, this typically relates to Safety Instrumented Systems designed to prevent or mitigate major accident scenarios by taking defined protective actions when hazardous conditions arise.

Functional safety ensures that automatic protection systems are reliable, appropriate and aligned to identified risk reduction requirements.

In high-hazard industries, this typically involves Safety Instrumented Systems (SIS) designed to:

  • Detect abnormal conditions
  • Take the process to a safe state
  • Prevent escalation to major accident scenarios

Functional safety is not limited to design. It is a lifecycle discipline, spanning specification, design, verification, operation and ongoing performance management.

Our functional safety services are delivered by a team of functional safety engineers with practical experience across high-hazard and regulated industries.

Functional safety focuses on ensuring that risk reduction measures are reliable, independent and effective.

This includes:

  • Identification of safety functions through HAZOP and LOPA
  • Definition of required risk reduction
  • Specification of Safety Instrumented Functions (SIFs)
  • Allocation of Safety Integrity Levels (SIL)
  • Design and verification of SIS

It provides a structured framework for demonstrating that instrumented protection layers are sufficient to reduce risk to ALARP.

Safety Integrity Level assessment determines the level of risk reduction required from a Safety Instrumented Function. This may be informed by LOPA, risk graph analysis or company standards.

SIL verification confirms that the proposed hardware and architecture can achieve the target SIL under defined assumptions.

This ensures that automatic protection systems are neither under specified nor unnecessarily complex.

They are determined based on:

  • Severity of consequence
  • Frequency of demand
  • Existing protection layers
  • Target risk reduction

Typical SIL levels include:

SIL LevelRisk Reduction Factor (Typical)
SIL 110 – 100
SIL 2100 – 1,000
SIL 31,000 – 10,000

SIL determination is typically carried out using LOPA or equivalent methods, ensuring consistency with wider process safety studies.

Where SIL2 or SIL3 functions are required, careful design is essential

This includes:

  • Clear definition of safety functions
  • Specification of sensors, logic solvers and final elements
  • Redundancy and voting architecture
  • Consideration of common cause failure
  • Diagnostic coverage
  • Integration with basic process control systems

Design decisions must align with operational reality and maintenance capability.

Functional safety in the process sector is generally aligned with:

  • IEC 61508 for functional safety of electrical, electronic and programmable electronic (E/E/PE) safety-related systems
  • IEC 61511 for safety instrumented systems in the process industry
  • Health and Safety Executive guidance
  • EEMUA guidance on alarms and proof testing

Compliance requires structured documentation, verification and ongoing assurance.

Functional Safety Assessment is a formal review carried out at defined stages of the project lifecycle. Typical stages include:

Concept & Design

  • Identification of safety functions through HAZID / HAZOP
  • Early LOPA and risk screening
  • Identification of potential SIS requirements

FEED and Detailed Design

  • SIL determination and verification
  • Safety Requirements Specification (SRS) development
  • SIS architecture definition
  • Instrumentation and control philosophy alignment

Construction & Commissioning

  • Functional safety verification
  • Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT)
  • Loop checks and system validation

Operation & Maintenance

  • Proof testing and performance monitoring
  • Functional safety assessments (FSA)
  • Management of Change (MoC) for SIS modifications

This lifecycle approach ensures that functional safety performance is maintained over time, not just achieved at design stage.

Functional Safety Assessment and Design support may include:

  • Functional Safety lifecycle gap analysis
  • Stage specific Functional Safety Assessments
  • SIL determination and verification reports
  • Safety Requirement Specification development
  • Safety Instrumented Function design documentation
  • Proof test procedure preparation
  • Alarm rationalisation studies
  • Ongoing assurance and periodic review

Deliverables are structured to be clear, auditable and regulator ready.

IDEA’s Experience Supporting Functional Safety Across Sectors

IDEA has extensive experience supporting functional safety assessment and design across Scotland, the UK and Europe in high hazard sectors.

Our team includes TÜV certified functional safety engineers who work closely with process, mechanical and control disciplines to ensure Safety Instrumented Systems are practical, compliant and aligned with lifecycle risk management.

We integrate functional safety with HAZOP, LOPA, DSEAR, COMAH and asset integrity activities to ensure consistency and traceability.

Our experience includes:

  • Chemical manufacturing with high consequence reaction and storage risks
  • Distilled spirits facilities with flammable vapour hazards
  • Life sciences and pharmaceutical operations handling flammable solvents
  • Biotechnology facilities
  • Energy and hydrogen projects requiring robust automatic protection

Frequently Asked Questions

Quick answers to questions you may have about our services

A Functional Safety Assessment is a structured review carried out at defined stages of the safety lifecycle to confirm that Safety Instrumented Systems comply with relevant standards and meet required risk reduction targets.

SIL2 or SIL3 may be required where hazard analysis identifies significant risk reduction needs that cannot be achieved through basic process control or passive safeguards alone.

While not law in itself, IEC 61511 is widely recognised as the appropriate standard for Safety Instrumented Systems in the process industry and is commonly referenced in regulatory expectations.

Safety Instrumented Systems should be reviewed periodically, particularly after modifications, changes in process conditions or significant incidents.

CONTACT US

Talk to Our Functional Safety Experts

If you are developing new Safety Instrumented Functions, reviewing existing systems or preparing for regulatory scrutiny, our Functional Safety experts can provide proportionate and technically robust support aligned to your lifecycle stage and sector.

Subscribe

* indicates required