Energy Efficiency Audit for an Aquaculture Feed Manufacturing Facility

An aquaculture feed manufacturer engaged IDEA to carry out a Type 2 detailed energy audit of an energy-intensive feed manufacturing facility, aligned with ISO 50002 and structured to support an ESOS submission. IDEA reviewed electrical and thermal energy use across all major production stages, developed energy balances and a Sankey diagram, and identified and prioritised energy performance improvement opportunities using the energy management hierarchy.

At a glance

  • Sector: Aquaculture feed manufacturing.
  • Scope: Type 2 detailed energy audit aligned with ISO 50002 and ESOS.
  • Disciplines: Process engineering and electrical energy assessment.
  • Outcome: A prioritised set of energy performance improvement actions and ESOS-ready supporting evidence.

Client Overview

The client operates an energy-intensive aquaculture feed manufacturing facility and needed a clear, quantified understanding of its electrical and thermal energy use in order to assess improvement opportunities.

Feed manufacturing for aquaculture is a continuous, multi-stage process spanning intake, grinding, extrusion, drying, coating, cooling and dispatch, each with its own electrical and thermal energy demands. Without a structured audit, opportunities for energy reduction and heat recovery can be difficult to identify and prioritise with confidence.

The challenge: understanding energy use across a complex, data-limited site

The challenge was to build a robust, site-specific picture of electrical and thermal energy use across multiple significant energy users, in a facility where not all energy data was readily available.

  • An energy-intensive facility with multiple significant energy users across intake, grinding, extrusion, drying, coating, cooling and dispatch.
  • Gaps in existing metering and monitoring data requiring a site-specific measurement plan.
  • The need to distinguish energy efficiency and heat recovery opportunities from fuel-switching or supply-side options, and to prioritise them appropriately.
  • A requirement for the audit to be robust enough to support the client's ESOS compliance obligations.

IDEA's role

IDEA carried out a Type 2 detailed energy audit fully aligned with ISO 50002, structured to also meet UK Energy Savings Opportunity Scheme (ESOS) requirements for scope, data quality and reporting.

  • Reviewed process and instrumentation diagrams and available energy data ahead of a site visit.
  • Validated existing metering, monitoring and data availability for each significant energy user.
  • Developed a site-specific measurement plan to close identified data gaps.
  • Built thermal and electrical energy balances, energy flow diagrams and a Sankey diagram of site energy use.

Reviewing significant energy users across the process

 IDEA reviewed each major production stage as a significant energy user, so that improvement opportunities could be identified and prioritised stage by stage.

  • Intake and storage
  • Grinding
  • Extrusion
  • Drying
  • Coating
  • Cooling
  • Product dispatch

Assessing opportunities using the energy management hierarchy

Improvement opportunities were assessed using the energy management hierarchy, prioritising prevention, reduction and reuse ahead of recycling, disposal, fuel switching or new supply-side solutions.

Each opportunity was evaluated against the existing energy baseline for technical feasibility, economic viability and environmental benefit, so that energy efficiency and heat recovery measures were considered before any change of fuel or supply technology.

What we delivered

IDEA delivered a baseline energy assessment, a structured significant energy user review, an electrical network review and a prioritised set of energy performance improvement actions.

  • Baseline energy, utilities, emissions and effluent assessment.
  • Significant energy user review and a site-specific measurement plan.
  • Electrical network review, load schedule and equipment efficiency review.
  • Prioritised energy saving, heat recovery and low-carbon utility options.
  • An end-of-stage report and stakeholder presentation to support next-step decisions.

Results and outcome

The audit gave the client a quantified, site-specific understanding of its energy use and a prioritised set of energy performance improvement actions to take forward, supported by evidence suitable for its ESOS submission.

  • A validated energy baseline and energy balance covering electrical and thermal systems across the site.
  • Energy flow diagrams and a Sankey diagram illustrating how energy is distributed, transformed and lost across the process.
  • A prioritised set of energy performance improvement actions ranked by potential savings, complexity and cost-effectiveness.
  • Supporting evidence structured to assist the client's ESOS compliance submission.
  • A clear basis for deciding which opportunities to progress to further feasibility, design or tendering.

Why IDEA for industrial energy audits

IDEA combines ISO 50002 aligned audit methodology with multidisciplinary process and electrical engineering expertise, giving clients a technically robust and independent view of their energy use.

  • Audits fully aligned with ISO 50002 and structured to UK ESOS requirements.
  • Experience auditing energy-intensive, multi-stage manufacturing processes.
  • A structured approach to closing data gaps through site-specific measurement planning.
  • Independence from equipment suppliers, so recommendations are based on technical, economic and environmental merit alone.

Frequently Asked Questions

A Type 2 (detailed) energy audit, as defined in ISO 50002, provides a quantitative analysis of a site's energy use, including energy balances, significant energy user reviews and prioritised energy performance improvement actions. It goes beyond a walk-through review to support informed investment decisions.

ISO 50002 sets out internationally recognised requirements and guidance for carrying out an energy audit, covering planning, data collection, measurement, analysis and reporting, so that audits are consistent, repeatable and technically robust.

The UK Energy Savings Opportunity Scheme (ESOS) requires qualifying organisations to carry out compliant energy audits at regular intervals. A Type 2 audit aligned with ISO 50002 and structured to ESOS requirements can provide supporting evidence for an ESOS submission, alongside review and sign-off by a qualified ESOS Lead Assessor.

A significant energy user is a piece of equipment, system or process that accounts for a substantial share of a site's energy consumption. Identifying SEUs allows an energy audit to focus data collection and analysis where it will have the most value.

The energy management hierarchy prioritises options in the order prevent, reduce, reuse, recycle and dispose. It encourages energy efficiency and heat recovery measures to be considered ahead of fuel switching or supply-side solutions, so that demand is addressed before investment in new supply.

A completed audit typically results in a prioritised list of energy performance improvement actions, ranked by potential savings, complexity and cost-effectiveness. These can then be taken forward to further feasibility, design or tendering, depending on the client's priorities.

CONTACT US

Need a clear, quantified view of your site's energy use?

If your facility is energy-intensive, has multiple significant energy users, or needs ESOS-ready evidence to support investment decisions, IDEA can carry out a Type 2 detailed energy audit aligned with ISO 50002, from baseline assessment through to a prioritised set of energy performance improvement actions.

Subscribe

* indicates required